Glycerin Canned Liquid Equipment Filling Machine

Product Details
Customization: Available
Cooling Way: Air Cooling
Control: Semi-Automatic
Manufacturer/Factory, Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
8000000 RMB
Plant Area
501~1000 square meters
  • Glycerin Canned Liquid Equipment Filling Machine
  • Glycerin Canned Liquid Equipment Filling Machine
  • Glycerin Canned Liquid Equipment Filling Machine
  • Glycerin Canned Liquid Equipment Filling Machine
  • Glycerin Canned Liquid Equipment Filling Machine
  • Glycerin Canned Liquid Equipment Filling Machine
Find Similar Products
  • Overview
  • Product Description
  • Certifications
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
RPS-YCS-5
Style
Portable
Shielding Gas
No Need
Electric Current
AC
Type
Intelligent Fluid Filling Equipment
Filling Range
0.1~5000ml
Filling Speed
0.1~500ml/S (Programmable)
Weight
480kg
Application
Filling Liquid
Transport Package
Wooden Cases
Specification
(L x W x H) 1200 x 880x 1700mm
Trademark
MASCOT
Origin
China
HS Code
8422301090
Production Capacity
100 Sets/Months

Product Description

Product Description

Product usage:  This equipment is a fully automatic oil filling device specifically developed by our company to meet the production needs of pressure gauge manufacturers. The device can perform fluid filling inside instruments and meters. It features an all-steel sheet metal integrated body, with the oil filling section made of SUS304 material. The design is innovative and the appearance is simple and elegant. A large 10.1-inch screen is used for operation, making parameters and filling dynamics clear at a glance, ensuring easy and convenient use.
2. The equipment is equipped with an external heat fluid heating device inside, featuring a constant temperature and voltage protection system, making the operation process extremely safe and temperature control very convenient. The equipment uses a high-precision plunger pump for filling, with precise electronic cylinders for measuring the filling volume, and is driven by a Yaskawa servo system. The filling accuracy can reach ±0.2g (for gasoline).
3. The equipment uses a parameterized formula design (as shown in the figure on the right) to store filling parameters for 32 products. When switching products is required, the parameter formula can be directly called according to the product and fluid characteristics.
4. The equipment can be set to submersible filling, equipped with a drip-proof system for filling, and can set the filling speed, liquid injection delay, flow control, and fluid temperature control. It is also equipped with overload alarms, low oil alarms, automatic counting, automatic error correction, automatic frequency conversion, and filling data storage functions.
 

Chapter one: Overview of equipment

 

1.1 Equipment functions

This equipment is designed for the internal fluid precision filling of instruments and meters, suitable for the quantitative filling of high viscosity fluids such as glycerin, silicone oil, thermal oil, etc., and has the following core functions:
High precision filling: using plunger pump + servo cylinder metering, filling accuracy up to ±0.2g (glycerin medium).
Temperature control: external heat fluid heating device (20~150ºC), support constant temperature protection and over-temperature alarm.
Intelligent management: supports 32 sets of formula storage, one-click parameter switching, and adapt to the production needs of multiple varieties.
Safety protection: equipped with overload alarm, oil shortage detection, anti-dripping system and three-level emergency stop protection.
 

1.2 Structural characteristics

Body design: the fuselage is made of steel sheet metal (1.5mm thick), which is highly impact-resistant; the oil filling part is made of SUS304 stainless steel, which is corrosion-resistant and meets GMP standards.
Human-computer interaction: 10.1 inch industrial touch screen (resolution 1280 x 800), real-time display of filling parameters, temperature curve and alarm information.
Modular layout: filling module, heating module and control module are divided into independent zones for easy maintenance.

1.3 Application areas

Medical equipment (e.g., blood pressure monitors, ventilators)
Precision instruments (sensors, optical devices)
Industrial valves and hydraulic components
 

Chapter two: Equipment technical parameters

2.1 Basic parameters

project parameter
Filling accuracy ± 0.2g (glycerol medium)
Filling range 0.1~5000ml
Temperature control accuracy ±0.5ºC
Filling speed 0.1~500ml/s (programmable)
power requirement AC 220V± 10%,50Hz, power 5.5kW
Overall weight of the machine 280kg

2.2 Core component parameters

assembly specifications
ram pump Travel 150mm, maximum pressure 0.5MPa
Servo electric cylinder The repeated positioning accuracy is ±0.01mm and the thrust is 500N
heat unit Power 3kW, heating rate ≥5ºC/min
Weighing module Range 0~10kg, resolution 0.01g






 

Chapter three:Hardware configuration list



 

3.1 List of major components

Component name Model/specification brand quantity
PLC controller FX5U-32MT/ES Mitsubishi 1
Servo drive system IS620P + 400W motor Huichuan 2
touch screen TPC7062Ti Kunlun is in a state of flux 1
temperature sensor PT100 (Class A accuracy) OMEGA 3
ram pump ZJB-25 Custom-made domestic products 1

 

3.2 Description of key materials

Fluid pipe: SUS304 Stainless steel seamless pipe (inner wall polished Ra≤0.8μm)
Seal: Fluororubber (temperature resistant-20~200ºC)
Body frame: Q235 cold rolled steel plate (surface electrostatic spraying treatment)



 

Chapter four: Operation process specification

4.1 Startup preparation

Safety check: confirm that the emergency stop button is reset and there is no leakage in the air pressure pipeline.
Power-on preheating: After starting the equipment, the heating module automatically heats up to the set temperature (default 45ºC).
Filling head installation: Select the hole size according to the fluid viscosity (standard 0.5mm/1.0mm/2.0mm).

4.2 Capping operation steps

Formula invocation: Select preset formula (such as P001-glycerin filling) from the touch screen.
parameter setting:
Filling quantity: 50.0g
Diving depth: 5mm (anti-splash)
Injection speed: 3 levels (medium speed mode)
Start filling:
Single mode: manually trigger single filling for debugging.
Continuous mode: automatic cycle filling, support production counting.

4.3 Emergency handling

Emergency stop operation: press the red emergency stop button, and the equipment will stop immediately and decompress.
Alarm reset: After clearing the alarm record on the HMI interface, the system is reinitialized.
 

Chapter five: Maintenance and maintenance specifications

5.1 Daily maintenance

project period Operation content
Seal ring inspection Per shift Check whether the O-ring is worn or aged
Filter cleaning everyday Remove the filter screen and clean it with ultrasonic waves for 30 minutes
Guide rail lubrication weekly Apply lithium grease (model #2)

5.2 Regular maintenance

project period Operation content
Servo system calibration Six months Perform origin reset + precision calibration
Descaling of heaters Three months Use a 5% citric acid solution for cyclic cleaning
Dust removal in electrical cabinets One month Use compressed air to blow (pressure ≤ 0.2MPa)

5.3 Fault troubleshooting guide

fault phenomenon Possible causes Rx
The filling volume is unstable Plunger pump seal wear Replace the pump head seal kit
The temperature fluctuates greatly PID parameter is out of balance Perform the automatic setting procedure
Servo alarm E05 Mechanical jamming Check whether there is any foreign interference on the guide rail of the electric cylinder
 

Chapter six: Precautions

6.1 Safety warnings

Overpressure is prohibited: the working pressure shall not exceed 0.5MPa to prevent pipe burst.
Heat warning: Do not touch the metal pipe when heated (surface temperature may be> 80ºC).
Electrical safety: the power supply must be disconnected and warning signs must be hung before maintenance.

6.2 Contraindications for use

Medium limitation: Do not fill strong acid, strong alkali or flammable and explosive fluid.
Environmental requirements:
temperature:5~40ºC
Humidity: ≤80%RH (no condensation)
attendant exclusion:
Do not open the protective door during operation
Do not start the pump body in the absence of oil

6.3 Long-term disuse management

Emptying fluid: When the machine is stopped for more than 7 days, the pipeline should be cleaned with alcohol and dried.
Battery maintenance: PLC backup battery is replaced every 2 years (model FX-40BL).
 

 